Measurement pages
|
Page |
Displayed measurements |
Description |
Note |
|---|---|---|---|
|
1 |
kWh+ TOT |
Imported active energy (TOTAL) |
|
|
2 |
kWh- TOT |
Exported active energy (TOTAL) |
Not available in PFA and SFA models |
|
3 |
kW |
Active power |
|
|
4 |
V L-N |
Voltage |
|
|
5 |
A |
Current |
|
|
6 |
PF |
Power factor |
|
|
7 |
Hz |
Frequency |
|
|
8 |
THD V |
Voltage THD |
|
|
9 |
THD A |
Current THD |
|
|
10 |
kvarh+ TOT |
Imported reactive energy (TOTAL) |
Not available in SFA models |
|
11 |
kvarh- TOT |
Exported reactive energy (TOTAL) |
Not available in SFA models |
|
12 |
kvar |
Reactive power |
Not available in SFA models |
|
13 |
kVAh |
Apparent energy (TOTAL) |
Not available in SFA models |
|
14 |
kVA |
Apparent power |
Not available in SFA models |
|
15 |
kW dmd |
Demand active power |
|
|
16 |
kW peak dmd |
Peak demand active power |
|
|
17 |
kWh T1 |
Imported active energy, tariff 1 |
|
|
18 |
kWh T2 |
Imported active energy, tariff 2 |
|
|
19 |
h (kWh+) TOT |
Run hour meter (imported energy) |
|
|
20 |
h (kWh-) TOT | Run hour meter (exported energy) |
Not available in PFA and SFA models |
|
21 |
h (ON time) TOT | Run hour meter (ON time) TOT |
|
|
22 |
kWh+ PAR |
Imported active energy (PARTIAL) |
Not available in SFA models |
|
23 |
h (kWh+) PAR |
Run hour meter (imported energy, PARTIAL) PARTIAL |
Not available in SFA models |
|
24 |
kWh- PAR |
Exported active energy (PARTIAL) |
Not available in PFA and SFA models |
|
25 |
h (kWh-) PAR |
Run hour meter (exported energy, PARTIAL) |
Not available in PFA and SFA models |
SETTINGS menu
This menu allows to set the parameters.
|
Page title |
Sub-menu |
Description |
Values |
Default values |
Note |
|---|---|---|---|---|---|
|
Meas |
- |
Measurement mode |
A (easy connection) B (bidirectional) |
A |
Non MID only |
|
DMD |
- |
DMD interval |
1 min 5 min 10 min 15 min 20 min 30 min 60 min |
15 min |
|
|
inPut |
- |
Digital input |
Tariff (tariff management) Status (remote status) P st (Start/stop partial meters) P res (partial meter reset) |
Status |
|
|
RS485 |
Addr |
Address |
1 to 247 |
1 |
|
|
PArity |
Parity |
NO/EVEN |
no |
||
|
bAud |
Baudrate |
9.6 kbps 19.2 kbps 38.4 kbps 57.6 kbps 115.2 kbps |
9.6 kbps |
||
|
StoP bit |
Stop bit |
1 or 2 |
1 |
||
|
M bus |
Pri Add |
Primary address |
0 to 250 |
0 |
|
|
bAud |
Baudrate |
0.3 kbps 2.4 kbps 9.6 kbps |
2.4 kbps |
||
|
Output |
Fun |
Function |
Off PuLSE (kWh+): pulse output linked to kWh+ PuLSE (kWh-): pulse output linked to kWh- ALArM: linked to alarm status |
PuLSE (kWh+) |
|
|
durAt |
Pulse duration |
30 ms 100 m |
30 ms |
||
|
PuLSES |
Pulse weight (pulses/kWh) |
0.1/1/10/100/500/1000 |
1000 |
||
|
StAtuS |
Output status |
No (normally open) Nc (normally closed) |
No |
||
|
ALARM |
EnAbLE |
Enable |
ON/OFF |
OFF |
|
|
VAriAb |
Monitored variable |
kW kVA Kvar PF A V |
kW |
|
|
|
SEt 1 |
Set point 1 (activation) |
-1000.00 to 1000.00 |
0 |
|
|
|
Set 2 |
Set point 2 (deactivation) |
-1000.00 to 1000.00 |
0 |
|
|
|
dELAY |
Activation delay |
0 to 1000 s |
0 |
|
|
|
dISPL |
LiGHt |
backlight |
ON (always on) 1 min 2 min 5 min 10 min 15 min 30 min 60 min oFF: always off |
ON |
|
|
SC SAV |
Screensaver |
oFF home: homepage SLidE: slideshow |
home |
|
|
|
HOME |
homepage |
1 to 25 |
1 |
Only 1 in PFA or SFA models Only 1 or 2 in PFB models |
|
|
PAGES |
Page filter |
ALL FiLtEr |
ALL |
|
|
|
PASS |
Password enabling for the SETTINGS and RESET menu |
0 (not protected) to 9999 |
0 (not protected) |
|
|
|
bAcK --- |
- |
Exit |
- |
- |
|
INFO menu
This menu allows to display the set parameters.
|
Page title |
Description |
Notes |
|---|---|---|
|
YEAr |
Production year |
|
|
Sn |
Serial number |
Sliding digits |
|
FW rEV |
FW revision |
|
|
MEAs |
Measurement type |
|
|
dMd |
Demand calculation interval |
|
|
Input |
Digital input function |
|
|
Addr |
Address |
|
|
bAud |
Baudrate (kbps) |
|
|
PArity |
Parity |
|
|
StoP b |
Stop bit |
|
|
PriAdd |
M-Bus primary address |
|
|
bAud |
M-Bus baudrate |
|
|
SECAdd |
M-Bus secondary address |
|
|
output |
Digital output function |
|
|
StAtuS |
Current output status |
|
|
durat |
Pulse output duration |
|
|
PuLSE |
Output pulse weight |
|
|
ALArM |
Alarm enabling |
|
|
VAr |
Linked variable |
|
|
SEt 1 |
Alarm activation set point |
|
|
SEt 2 |
Alarm deactivation set point |
|
|
dELAY |
Alarm activation delay |
|
|
LIGHt |
Backlight timer |
|
|
tEMP |
Internal microcontroller temperature |
Available only in PFA70 and PFB70 models. For further information refer to the communication protocol |
|
CHECKSuM |
Firmware checksum |
|
RESET menu
This menu allows to reset the following settings:
|
Page |
Page title |
Description |
|---|---|---|
|
1 |
PArtiAL |
It resets the partial meters |
|
2 |
DMD |
It resets the dmd calculation |
|
3 |
tAriFF |
It restores the factory settings |
|
4 |
total |
It resets the total meters |
|
5 |
FACtor |
It resets the device to factory settings |
|
6 |
Back--- |
Back to main menu |
Communication Interface
Available setting parameters:
|
Parameter name |
Description |
Available on UI |
Available on RS485 |
Available on Mbus |
||
|---|---|---|---|---|---|---|
| S1 Model | M1 Model | O1 Model | only S1 Model | only M1 model | ||
|
Password |
Password for accessing parameters via UI | X | X | X | X |
|
|
DMD time |
Time for DMD calculation (average on measures) | X | X | X | X |
|
|
Alarm enable |
Enable or disable the virtual alarms | X | X | X | X |
|
|
Alarm link |
Variable linked to the alarm | X | X | X | X |
|
|
Alarm SET1 |
Alarm setpoint 1 | X | X | X | X |
|
|
Alarm SET2 |
Alarm setpoint 2 |
X | X | X | X |
|
|
Alarm Delay |
Alarm delay |
X | X | X | X |
|
|
Measure mode |
Type of measurement |
X* | X* | X* | X* |
|
|
Digital input selection |
Function of the digital input |
X | X | X | X |
|
|
Page Filter |
Filter on real-time pages |
X* | X* | X* | X* |
|
|
Screen saver |
Indicates what happens after 300s of inactivity |
X* | X* | X* | X* |
|
|
Home page |
Page on startup or when the UP button is pressed for 2s |
X** | X** | X** | X** |
|
|
Backlight |
Backlight time |
X | X | X | X |
|
|
Screen saver time |
Page rotation time when using screensaver |
|
|
|
X*** |
|
|
Tariff management |
Configuration to enable the tariff management via serial |
|
|
|
X |
|
|
Quick setup |
Restores the initial quick setup menu |
|
|
|
X |
|
|
Startup current |
Set the start-up current only for hour counters |
|
|
|
X |
|
|
Current direction |
Direction of the input current |
|
|
|
X*** |
|
|
Tariff selection |
Tariff selection |
|
|
|
X |
X |
|
Pages cfg |
Dedicated register for each Real time page to configure the visibility |
|
|
|
X* |
|
|
Device name |
Registers to set a device name |
|
|
|
X |
|
|
RS485 Address |
RS485 address |
X |
|
|
X |
|
|
RS485 Baud |
RS485 baudrate |
X |
|
|
X |
|
|
RS485 Parity |
RS485 parity |
X |
|
|
X |
|
|
RS485 Stop |
RS485 Stop bits |
X |
|
|
X |
|
|
Delay on reply |
Minimum time before answering |
|
|
|
X |
|
|
MBUS Address |
MBUS primary address |
|
X |
|
X | |
|
MBUS Baud |
MBUS baudrate |
|
X |
|
X | |
|
OUT Config. |
Output configuration |
|
|
X |
|
|
|
OUT Type |
Output NO or NC |
|
|
X |
|
|
|
Pulse duration |
Pulse duration |
|
|
X |
|
|
|
Pulse weight |
Pulse weight |
|
|
X |
|
|
* = Read-Only on MID models
** = Home page can be set only to 1 in PFA and SFA and between 1 and 2 on PFB
*** = Not available on MID models